Brand Name : Coolmay

Model Number : QM3G-100FH-24MR

Certification : CE

Place of Origin : Shenzhen

MOQ : 1 pcs

Price : Negotiable

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 100,000 pcs per month

Delivery Time : 3-7 work days

Packaging Details : Packed with standard carton box

CPU : 32bit CPU 408MHz

Type : 10" TFT

Dimension : 275*194*36mm

Cutout size : 262*180mm

Analog I/O : (optional) Max 16AI/8AO

DI/DO : Max 30DI/30DO (max 28MR)

Contact Now

275*194*36mm Portrait Display Integrated HMI PLC RS Protocol RS232

Parameter:

Display

Dimension

275*194*36mm

Cutout size

262*180mm

Type

10"TFT

Feature

60K-color resistive touch screen, supports portrait display

Memory

RAM

64MB

ROM

NOR Flash 16MB

CPU

32bit CPU 408MHz

I/O

DI/DO

Max 30DI/30DO (max 28MR)

DI/DO level

Input: Passive NPN, public terminal isolated

Transistor output: Low level NPN, COM connect to negative; Relay output: Normally open dry contact

DO type and load

Relay MR/MOS tube, MOS tube: 2A/point, 4A/4 point COM, 5A/12 point COM; MR: 2A/point, 5A/12 point COM.

Analog I/O

(optional)

Max 16AI/8AO

AI type (optional)

Thermocouple E/E_/K/K_/S/S_/T/T_/J/J_ / PT100/ PT1000/ NTC10K/ NTC50K/ NTC100K/

0~10V/ 0~5V/ 0~20mA/ 4~20mA/ -5V~5V/ -10V~10V / mixed

AO type (optional)

0~10V /0~5V/ 0~20mA/ 4~20mA/ mixed/

-5~5V/ -10~10V (2AO for 1 minus voltage)

High-speed function

High-speed counting

Single phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz,

or 2 ABZ 60KHz + 1 AB phase 10 KHz

High-speed pulse

8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz.

High-speed counting + high-speed pulse < 480KHz

Connection

HMI

Type-B HMI download port (can download PLC program through the USB penetrating function), RS232

1 RS485 (changed from default RS232)

PLC

1 Mini USB, 1 RS232 (program port)

1 RS485 or 2 RS485 COM ports (one is changed from the default RS232 port)

CAN (2.0A/B) port, Ethernet port, WIFI (will occupy default RS232 port)

Software

HMI

Coolmay mView HMI Programming Software

PLC

Compatible with Mitsubishi GX Developer 8.86 and WORKS 2

Advantage:

◆Upper computer programming software compatible with Works 2/GX Developer8.86 (supports Ladder diagram and SFC language, does not support structured programming/labels).

◆Powerful, compatible with FX3G/FX3U/FX3S PLC, high processing speed.

◆Military level 32 bit CPU adopted, which is faster and more adapted to industrial environment of high electromagnetic interference.

◆Special encryption, prevent illegal reading thoroughly. 8-bit encryption, 12345678 as password can thoroughly prevent reading of ladder logic program.

◆Clock supported, rechargeable battery adopted.

◆Default with 1 HMI download port, 2 PLC programming ports (RS232/MiniB USB port or Type-C), and one USB port.

◆PLC is optional to add 1 485 or 2 485(One of the 485 ports is changed from the default 232 port)/CAN/network port/WIFI(which will occupy the default port 232); HMI defaults to 1 RS232, optional 1 RS485.

◆Support Mitsubishi programming protocol/MODBUS protocol/RS protocol/BD board protocol, easily realize PLC interconnection and communication with external devices.

◆High-speed counting, conventionally single-phase 6 channels 60KHz or AB (Z) phase 2 channels 60KHz + AB phase 1 channel 10KHz. High-speed pulse, conventionally 8 channels: Y0-Y3 is 100KHz, Y4-Y7 is 10KHz. High-speed counting+ High-speed pulse cannot exceed 480KHz; acceleration and deceleration are independent.

Network communication:

The network is automatically detected after power-on. When there is a network chip, M8193=1, the network is ready.

The involved special relays, special registers, and registers used by the IP address are as follows:

Function description

Network usage

Remarks

Network preparation

M8193

Write network address

M8197

MODBUS timeout

M8062

IP address conflict

M8063

Mitsubishi function and MODBUS switch sign

D8395

Set during ADPRW instruction

D8397=3

Router address

R23800 R23801

Mask address

R23802 R23803

MAC address

R23804~R23806

Local IP address

R23807 R23808

Destination IP address

R23810 R23811

port

R23812

Default 502

RD3A/WR3A instruction cycle times

R23813

MODBUS timeout time

R23814

Number of packets sent

R23815

Number of received packets

R23816

M8193:=1 Indicates that there is a network chip, and the network is ready

M8197:=1 Write the network address and reset automatically.

M8062:=1 Indicates MODBUS timeout, MODBUS_TCP is used.

M8063:=1 Indicates an IP address conflict.

D8395:Mitsubishi function and MODBUS_TCP switch

D8395=0:Mitsubishi function

D8395=1: MODBUS_UDP slave station

D8395=2: MODBUS_UDP master station

D8395=3: MODBUS_TCP slave station

D8395=4: MODBUS_TCP master station

D8395=5: EtherNet/IP slave (server)

D8397: When using MODBUS_TCP for ADPRW instruction, D8397 needs to be set to 3.

R23800 and 23801 are router addresses. The default is 192.168.1.1. That is, R23800=0XC0A8, R23801=0X0101.

R23802 and 23803 are the mask addresses, and the default is 0 .0. 0 .0. That is, R23802=0, R23803=0.

R23804~23806 are MAC addresses, which are generated by the system and are basically not repeated. Can also be set. Note: The MAC address on the same network cannot be repeated, otherwise it will cause abnormal communication.

R23807 and R23808 are the IP addresses of this machine. The default is 192.168. 1.250, that is, R23807=0XC0A8, R23808=0X01FA.

R23810 and R23811 are MODBUS target IP,

R23812 port default 502

R23813 default=100 (number of cycles), which is the interval time between WR3A and RD3A sequence execution.

R23814 default = 20 (200ms), it is the MODBUS timeout time setting, only retry twice, each time = (R23814*5)ms.

R23815 is the number of MODBUS sent packets

R23816 is the number of MODBUS received packets.

Portrait PLC HMI Panel RS Protocol RS232 408MHz TFT Coolmay


Product Tags:

Portrait PLC HMI Panel

      

408MHz TFT PLC HMI Panel

      

RS Protocol Coolmay PLC HMI

      
China Portrait PLC HMI Panel RS Protocol RS232 408MHz TFT Coolmay wholesale

Portrait PLC HMI Panel RS Protocol RS232 408MHz TFT Coolmay Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Coolmay Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)